Filter Results By:

Products

Applications

Manufacturers

Showing results: 106 - 120 of 156 items found.

  • Quad Ammeter

    4014 - Red Phase Instruments Australia Pty Ltd.

    The Model 4014 integrates four ammeters for the direct and simultaneous reading of C.T. secondaries up to 10A during the setting up or checking of protection systems while they are in service with normal 50/60Hz primary currents flowing. The two terminals of each channel of the Model 4014 are connected in series with the C.T. secondary with all other equipment in the loop or directly across the C.T. secondary.

  • TEST BOX

    6280 TB - Standard Electric Works Co., Ltd

    ● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1

  • 12 D/A Outputs (±10 VDC or ±25 mA)

    DA1 - North Atlantic Industries

    The DA1 module features 12 independent D/A output channels with a full-scale range of ±10 VDC at ± 25 mA (max). The DA1 provides either voltage or current control loop modes that are programmable for the particular application. The DA1 module also offers external trigger/synchronization signal (RS422/485) capability, which provides/accepts a trigger signal to/from other module(s).

  • 200 Ampere Micro OHM Meters

    HL-200 - Neutronics Manufacturing Co.

    Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 200 is a direct reading tester, and uses a test current of 200A DC, resulting in true value and accurate measurements. Model HL- 200 adopts digital circuit technique and is used for measuring contact resistance of switch control equipment at test current of 200A DC. The measurements are accurate as the test is highly stable. HL- 200 is a new, fully automatic micro controlled tester that measures contact resistance at 200A DC with built in printer.

  • Lightning Current Generator

    Shanghai Guantu Technology Co., Ltd.

    The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.

  • Battery Pack Test System

    PRODIGIT Electronics Co, Ltd.

    *Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery.

  • Three Axis Helmholtz Coil Systems

    Macintyre Electronic Design Associa

    he MEDA turnkey closed loop magnetic field sources cancel the local ambient field as well as generate accurate and uniform magnetic fields in a control volume. The sources use Helmholtz coils driven by control currents to produce stable magnetic fields from 1 nT to 100,000 nT. The accuracy of the field in the control volume is better than 0.05% of the setting.

  • 100 Ampere Micro OHM Meters

    Neutronics Manufacturing Co.

    Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester,  and uses a test current of 100A DC,  resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new,  fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100

  • NI-9266 , 8-Channel C Series Current Output Module

    785046-01 - NI

    8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.

  • NI-9266, 8-Channel C Series Current Output Module

    785047-01 - NI

    8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.

  • NI-9266, 8-Channel C Series Current Output Module

    785047-02 - NI

    8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.

  • H/L Voltage Clamp Meters

    MEWOI Electronics Co.,ltd

    High Voltage Current Transformation Ratio Tester breaks traditional structure, specially designed for high and low voltage first and secondary loop current, variable ratio, and current leakage test; apply the latest CT technology and mask digital integration technology, composed of special high-voltage clamp, low voltage clamp, host, high voltage insulation rod and monitoring software, etc; its wireless transmission test data can penetrate multiple building obstacles with a straight-line distance of 30 meters.

  • Battery Charge And Discharge Test System

    9841 - PRODIGIT Electronics Co, Ltd.

    *Easy user interface*Measure Voltage, Current, Power, KWH, AH, Temperature, Reference Voltage*Accuracy Measure Time*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery. *The test result will be stored to ACCESS data

  • C Series Current Output Module

    NI

    The C Series Current Output Module features up to eight channels of simultaneous analog output. You can choose between enclosed and non-enclosed modules. Additionally, the C Series Current Output Module has built-in open-loop detection. This detection generates an interrupt in software when an open loop is detected, zeros outputs to ensure safety, and avoids driving actuators at system power-on. The C Series Current Output Module requires an external power supply and includes a channel-to-earth ground double isolation barrier for safety and noise immunity.The C Series Current Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Ground Fault Finder

    FST-JD200 DC - Foresight Electronics Co., Ltd.

    FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...

Get Help